Quantcast
Channel: Intel Communities : All Content - Servers
Viewing all 3917 articles
Browse latest View live

intel server board s1400fp2 - raid

$
0
0

Hi guys,


That might be a really simple question for some of you guys but does that board support fake raid only ?  In other words, does the O.s need to support the raid entirely ?  I do select raid mode in bios but i don't see how i can configure it in the bios...  I tried control -I , control -E   when the server boot up but nothing show up...

 

Does that board need a add-in card installed ?

 

I did read that board support software raid...does that mean O.S dependable ?

 

Thanks guys for your help.


I'm trying to setup raid10 with 4 hd's...


Fan tachometer reading of 0 RPM although fans are spinning, results in critical alert

$
0
0

Hello,

 

I have a problem with the server mainboard S1200SPL.

 

Quick information about the setup:

  • board resides in a non Intel chassis
  • 2 chassis fans (PWM)
  • 1 cpu fan (PWM)
  • BIOS, FRU and SDR are up-to-date
  • SDR was configured with other chassis option, fan 3 and 4 installed, also CPU fan installed option
  • Fans are set to acoustic mode in BIOS

 

Problem description:

  • all fans are marked as critical in the web frontend (red)
  • diagnostic lights blinking amber
  • fan speed reading of all three fans is 0 RPM
  • but all three fans are actually spinning at a low level

 

What I did so far:

  • changed values in SDR file and uploaded them to mainboard
  • "SDR Type C0/0A Records For Fan Sensor Scaling", section "OTHER"
    • values for fan 3 and 4 changed from 25000 RPM (hex: A861) to 1000 RPM (hex: E803) and 1500 RPM (hex: DC05), that are the new max values
    • value for processor fan changed from 25000 RPM (hex: A861) to 1900 RPM (hex: 6C07), that is the new max value
  • "Fan tachometer sensors", "OTHER" sections
    • "OTHER_FAN_3"
      • M=04h
      • Nominal Reading=80h (500 RPM)
      • Normal Minimum=7Ch (490 RPM)
      • Lower critical = 00h
      • Lower non-critical = 02h
    • "OTHER_FAN_4"
      • M=06h
      • Nominal Reading=7Fh (750 RPM)
      • Normal Minimum=66h (600 RPM)
      • Lower critical = 00h (0 RPM)
      • Lower non-critical = 11h (12 RPM)
    • "OTHER_PROC_FAN"
      • M=07h
      • Nominal Reading=49h (550 RPM)
      • Normal Minimum=43h (500 RPM)
      • Lower critical = 2Fh (350 RPM)
      • Lower non-critical = 35h (400 RPM)

 

The values of fan 4 were set to nearly 0 to test if the critical alert will go away, but it didn't. Sometimes fan 4 reports a valid RPM value of 400 RPM and status gets to normal. The fans are spinning in a slow mode so that the whole system is very quiet :-).

 

Questions:

  • are the fan readings influenced by some other values directly or indirectly in the SDR file, for example "Domain/Profile Dependent RECORDS" or the curves?
  • can the fan readings be fixed somehow?

 

A bit history: the chassis that I bought came with 3 3-pin-only-fans, that spinned up to 100%. The cpu fan was always a 4-pin fan. Before I changed the numbers in the SDR file the 3 chassis fans got a valid rpm read, but the cpu fan did not. After setting the values in the SDR file, the cpu got also a valid RPM value, but the chassis fans were spinning at 100%. I decided to exchange two of the chassis fan through 4-pin fans. The third chassis fan is disabled now. After placing the new fans in, all rpm values were set to 0 RPM and the status became critical although all fans are actually spinning. and the max rpm values are the same as before After that I lowered the critical values for the chassis fans but without any success.

Ubuntu server drivers for 2600WT PWM controller?

$
0
0

What Linux drivers are available for the PWM fan controller on 2600WT boards?  I ran sensors-detect followed by pwmconfig, but pwmconfig reports that "There are no pwm-capable sensor modules installed".  I'm running Ubuntu 16.04.1 server.  When I load the server heavily, the CPUs sometimes get throttled due to overheating.  As a workaround, I configured the fans to always run at a high RPM in the BIOS, but that's very noisy.

Intel Active System Console - Data is being retrieved, Please retry

$
0
0

ASC gives the above message.  I have removed ASC and RAID Web Console.  Rebooted and installed ASC only.  I have waited a day and still get the same message.

 

OS is Windows Server 2012

Server board is S5520HCR

 

Can anyone help please?

How to reset the superuser password for RMM2.

$
0
0

"Slight" problem. We lost the superuser password for one of our RMM2. I cannot find any procedure in any of the available documents, on how to reset the admin superuser password for this above module. Unfortunately no other users are defined on the RMM2.

Question: how to reset the superuser password on the RMM2? The server is physically accessible.

No jumpers on the RMM2

S5520SC workstation Board started making 5 beep

$
0
0

My computer with a S5520SC workstation Board has recently started making 5 beep before the normal bios post beep codes. Does anyone know what it means?

Thanks Vanda

What options might I have to upgrade SC5520 motherboard with dual xeon 5520's? CAD application and need more power.

$
0
0

Great machine, just need more power.  Hoping to be able to upgrade XEON's and add more ECC.  My last CFD calc ran more than 10 hours.

Thanks,

GPa

Help activating Intel Modular Server LUN Copier Key

$
0
0

Since the imskey.intel.com activation site is no longer functional, where can i activate my LUN Copier key?

 

I have the CMM and Paper Pack ID available for activation

 

thank you,


Want to upgrade workstation for CAD. Current SC5520 motherboard with dual Xeon 5520 quad cores. what is my best option to upgrade?

$
0
0

What options might I have to upgrade my workstation? Current configuration is Intel motherboard SC5520 with dual Xeon quad-cores, 5520, and 32g ECC RAM.  Everything works great just need more processing power.  Would like to optimize what I have if economically possible, before moving up to more expensive workstation.

S1200V3RPL: BMC turns off

$
0
0

Hello All !

S1200V3RPL (the new board) with the "Remote Management Module AXXRMM4Lite" module installed. BIOS updated to the latest version.

Board has a strange behaviour: when turn it off thought Web Console it turns off completely, with the BMC. There is only one LED on the board, that always lights (green) -- power (near the main power connector). LEDs on both NICs, status and ID (rear) all turned off. It goes without saying, that there is no ping and network connectivity to the Integrated BMC Web Console.

The BMC starts working when press on the Power Button on the front panel. System stays in the off mode, only the BMC turns on, initializes and work in ordinary mode (like when one turns on power source).

 

I tried:

  • To reflash firmware for the BIOS, BMC and ME using according recovery modes (in sequence, one by one, setting according jumper with full AC power down, like it was mentioned in Recovery notes);
  • to downgrade BIOS to the v03.01.0002;
  • run the board with the other power source.

S1200V3RPS Windows Server 2016

$
0
0

Hi!

 

Im about to reinstall my server from 2012r2 to 2016, does anyone know if this will work? I cant find any drivers for Windows Server 2016 on the support page.

Centos 7 installation on R23098WTTYSR

$
0
0

Hi All,

Are there any specifics about installing Centos 7 on a R2308WTTYSR Server?

How can i deploy OS from a USB?

 

Thank you in advance.

 

Vaios

Rmm4 Does not seem to be connecting to the network

$
0
0

Hello I have a intel s1400sp that i just installed a RMM4 LITE and Dedicated management nic into. I then followed the user guide and setup the server management tab under BMC LAN Configuration in the bios accordingly. I then saved pressing F-10 and plugged in the network. Both lights are yellow and blink slowly, yet when i try to connect to the RMM i cannot connect. I have also checked with my router, network mapper and cmd ping test and i cannot see or ping it. I have changed around the ip address, set to static and also dynamic, removed the dedicated management nic and tried using the onboard ethernet as well but the result is still unchanged.

intel server board s1400fp2 - raid

$
0
0

Hi guys,


That might be a really simple question for some of you guys but does that board support fake raid only ?  In other words, does the O.s need to support the raid entirely ?  I do select raid mode in bios but i don't see how i can configure it in the bios...  I tried control -I , control -E   when the server boot up but nothing show up...

 

Does that board need a add-in card installed ?

 

I did read that board support software raid...does that mean O.S dependable ?

 

Thanks guys for your help.


I'm trying to setup raid10 with 4 hd's...

Intel Server Board S5000PSL / Xeon L5320 -> Speed Stepping (Energy Consumption)

$
0
0

Hello,

I'm using a Intel S5000PSL Server Board with two Xeon L5320 CPUs and am having a problem with the power consumption.

The CPU does not step down to a lower power level.

 

Is there a way I can achieve that?

 

Here are some Informations from the server:

Board:

               Intel S5000PSL

BIOS Version: S5000.86B.15.00.0101.110920101604

 

OS: Microsoft Windows Server 2008 R2 Standard (x64) Build 7601 (with SP1)

 

2xCPU:

Processor Manufacturer: Intel(R) Corporation

Processor Version: Intel(R) Xeon(R) CPU L5320 @ 1.86GHz

External Clock: 1066 MHz

Maximum Clock Supported: 1866 MHz

Current Clock: 1866 MHz

CPU Socket: Populated

CPU Status: Enabled

Processor Type: Central Processor

Processor Voltage: 1.2 V

Processor Upgrade: ZIF

Socket Designation: CPU1

Processor Name: Intel Xeon L5320

Original Processor Frequency: 1866.7 MHz

Original Processor Frequency [MHz]: 1867

CPU ID: 000006F7

CPU Brand Name: Intel(R) Xeon(R) CPU L5320 @ 1.86GHz

CPU Vendor: GenuineIntel

CPU Stepping: B3

CPU Code Name: Clovertown LV

CPU S-Spec: SLA4Q, SLAC9

CPU Thermal Design Power (TDP): 50 W

CPU Max. Case Temperature (Tcase_max): 60 °C

CPU Type: Production Unit

CPU Platform: LGA771 (FC-LGA6)

Microcode Update Revision: 6B

Number of CPU Cores: 4

Number of Logical CPUs: 4

 

Memory Information:

Memory 8GB

Memory Speed: 667 MHz

Memory

[General information]

Total Memory Size: 8 GBytes

Total Memory Size [MB]: 8192

[Current Performance Settings]

Current Memory Clock: 332.4 MHz (5 : 4 ratio)

Current Timing (tCAS-tRCD-tRP-tRAS): 5.0-5-5-15

Read to Read Delay (tRD_RD) Same Rank: 3T

Write to Write Delay (tWR_WR) Same Rank: 2T

Read to Write Delay (tRD_WR) Same Rank: 4T

Write to Read Delay (tWR_RD) Same Rank (tWTR): 8T

Write to Read Delay (tWR_RD) Different Rank: 2T

Read to Precharge Delay (tRTP): 3T

Write to Precharge Delay (tWTP): 16T

Write Recovery Time (tWR): 5T

RAS# to RAS# Delay (tRRD): 3T

Row Cycle Time (tRC): 20T

Refresh Cycle Time (tRFC): 28T

 

Drives:

Raid-1: 2 Drives

Raid-6: 6 Drives (external controller)

 

 

Energy Settings in the OS are as followed:

Energiespareinstellungen_CPU.jpg

 

Intel Processor Diagnostic Tool:

Intel Processor Diagnostic Tool.jpg

 

CPU-Z reading max Multiplier:

CPU-Z.jpg

 

In the bios speed stepping was activated, and I do not know what to do, to conserve some energy.

I hope you can help me to either find a setting, so I can put it into a more energy preserving mode when the power is not used.

Or if not have a recommendation on what to switch to, if it is not possible for some reasons.

 

Thank you very much in advance!


Fan tachometer reading of 0 RPM although fans are spinning, results in critical alert

$
0
0

Hello,

 

I have a problem with the server mainboard S1200SPL.

 

Quick information about the setup:

  • board resides in a non Intel chassis
  • 2 chassis fans (PWM)
  • 1 cpu fan (PWM)
  • BIOS, FRU and SDR are up-to-date
  • SDR was configured with other chassis option, fan 3 and 4 installed, also CPU fan installed option
  • Fans are set to acoustic mode in BIOS

 

Problem description:

  • all fans are marked as critical in the web frontend (red)
  • diagnostic lights blinking amber
  • fan speed reading of all three fans is 0 RPM
  • but all three fans are actually spinning at a low level

 

What I did so far:

  • changed values in SDR file and uploaded them to mainboard
  • "SDR Type C0/0A Records For Fan Sensor Scaling", section "OTHER"
    • values for fan 3 and 4 changed from 25000 RPM (hex: A861) to 1000 RPM (hex: E803) and 1500 RPM (hex: DC05), that are the new max values
    • value for processor fan changed from 25000 RPM (hex: A861) to 1900 RPM (hex: 6C07), that is the new max value
  • "Fan tachometer sensors", "OTHER" sections
    • "OTHER_FAN_3"
      • M=04h
      • Nominal Reading=80h (500 RPM)
      • Normal Minimum=7Ch (490 RPM)
      • Lower critical = 00h
      • Lower non-critical = 02h
    • "OTHER_FAN_4"
      • M=06h
      • Nominal Reading=7Fh (750 RPM)
      • Normal Minimum=66h (600 RPM)
      • Lower critical = 00h (0 RPM)
      • Lower non-critical = 11h (12 RPM)
    • "OTHER_PROC_FAN"
      • M=07h
      • Nominal Reading=49h (550 RPM)
      • Normal Minimum=43h (500 RPM)
      • Lower critical = 2Fh (350 RPM)
      • Lower non-critical = 35h (400 RPM)

 

The values of fan 4 were set to nearly 0 to test if the critical alert will go away, but it didn't. Sometimes fan 4 reports a valid RPM value of 400 RPM and status gets to normal. The fans are spinning in a slow mode so that the whole system is very quiet :-).

 

Questions:

  • are the fan readings influenced by some other values directly or indirectly in the SDR file, for example "Domain/Profile Dependent RECORDS" or the curves?
  • can the fan readings be fixed somehow?

 

A bit history: the chassis that I bought came with 3 3-pin-only-fans, that spinned up to 100%. The cpu fan was always a 4-pin fan. Before I changed the numbers in the SDR file the 3 chassis fans got a valid rpm read, but the cpu fan did not. After setting the values in the SDR file, the cpu got also a valid RPM value, but the chassis fans were spinning at 100%. I decided to exchange two of the chassis fan through 4-pin fans. The third chassis fan is disabled now. After placing the new fans in, all rpm values were set to 0 RPM and the status became critical although all fans are actually spinning. and the max rpm values are the same as before After that I lowered the critical values for the chassis fans but without any success.

Ubuntu server drivers for 2600WT PWM controller?

$
0
0

What Linux drivers are available for the PWM fan controller on 2600WT boards?  I ran sensors-detect followed by pwmconfig, but pwmconfig reports that "There are no pwm-capable sensor modules installed".  I'm running Ubuntu 16.04.1 server.  When I load the server heavily, the CPUs sometimes get throttled due to overheating.  As a workaround, I configured the fans to always run at a high RPM in the BIOS, but that's very noisy.

I have an server with S2600CP mother borad. Now windows 2008 R2 installed in it with 8x4TB HDD. Please let me know the maximum capacity of Hard Drive for this Mother Boards. If I upgrade the OS to 2012 will this mother board support 64 TB disk.

$
0
0

Hello All,

 

I have an server with S2600CP mother borad. Now windows 2008 R2 installed in it with 8x4TB HDD. Please let me know the maximum capacity of Hard Drive for this Mother Boards. If I upgrade the OS to 2012 will this mother board support 64 TB disk. 8x8 TB HDD.

 

 

Many Thanks,

Austin Jose

How do I update the BIOS on a very old S2600CP motherboard?

$
0
0

Hi,

 

I've just been given an ancient, refurbished S2600CP2J motherboard complete with CPUs and RAM and would like to get it fully working again.

 

The obvious first step is to update the BIOS but the oldest EFI update package available (01.02.003) states that I need to have at least version 01.01.1002 before starting or "the update process may render the system not operatable!"

 

According to the BIOS screen, my system is currently SE5C600.86B.99.99.x034, build date 08/23/2011.

 

As I have no wish to kill the system before I get started, is there any way of upgrading it to 01.01.1002 as a minimum?

 

Thanks.

Материнская плата s2600KPF не могу настроить SOL

$
0
0

собственно вот

[root@head~]# ipmitool -H X.X.X.X -U ADMIN sol info 1

Password:

Info: SOL parameter 'Nonvolatile Bitrate (5)' not supported

Info: SOL parameter 'Volatile Bitrate (6)' not supported

Set in progress                 : set-complete

Enabled                         : true

Force Encryption                : false

Force Authentication            : false

Privilege Level                 : USER

Character Accumulate Level (ms) : 60

Character Send Threshold        : 96

Retry Count                     : 7

Retry Interval (ms)             : 500

Volatile Bit Rate (kbps)        : IPMI-Over-Serial-Setting

Non-Volatile Bit Rate (kbps)    : IPMI-Over-Serial-Setting

Payload Channel                 : 1 (0x01)

Payload Port                    : 623

 

 

 

Пользователь ADMIN является администратором в ipmi.

 

 

[root@node01 ~]# ipmitool -H node01-ipmi -U ADMIN sol set non-volatile-bit-rate 57.6

Password:

Error setting SOL parameter 'non-volatile-bit-rate': Parameter not supported

 

подскажите где проблема.

Viewing all 3917 articles
Browse latest View live