P4304XXSHCN with S1200V3RPL chassis fan speed

$
0
0

Does anyone have any information about thermal management of the following combination.

New P4304XXSHCN chassis with S1200V3RPL board and E3-1241v3 cpu with stock cooler.

Firmware updated to 02.02.0005

Machine power cycled.

The following issues are being experienced

  • Chassis fan speed/ noise about twice that of comparable HP or DELL machines
  • At a chassis fan speed of about 4400 RPM and above the air flow through the power supply is first stalled then reversed!
  • Aggregate Thermal Margin 1 reports values above what is reported to be CT (0 degrees C)


The following table list thermal information from the web console, Front Panel Temp = ambient temp

 

 

Front Panel Temp25262830323336
PCH Temp43464852535452
Sys Fan2040238227603528374440084416
CPU fan936948936936936996948
P1 Therm Margin-69-67-46-28-23-23-59
DIMM Therm Margin 1-57-56-55-44-41-41-48
BB EDGE Temp27292933363636
BB BMC Temp31323437394040
BB CPU VR Temp30313232494839
HSBP Temp28283032353638
Agg Thrm Mgn 1124791010

Any information great fully accepted